ISSUE 02WEDNESDAY, JUNE 3, 2026PRINT 06.2026

GEOMDIGEST

THE INSIDER PUBLICATION FOR COMPUTATIONAL GEOMETRY & DESIGN

GEOMDIGEST / PAPERS / TRANSFORMER-IMU-CALIBRATOR-DYNAMIC-ON-BODY-IMU-CALIBRATION-FOR-INERTIAL-MOTION-C-2025-673723
No code

Transformer IMU Calibrator: Dynamic On-body IMU Calibration for Inertial Motion Capture

2025 / ACM Transactions on Graphics / DOI 10.1145/3730937

In this paper, we propose a novel dynamic calibration method for sparse inertial motion capture systems, which is the first to break the restrictive absolute static assumption in IMU calibration, i.e., the coordinate drift R G′ G and measurement offset R BS remain constant during the entire motion, thereby significantly expanding their application scenarios. Specifically, we achieve real-time estimation of R G′ G and R BS under two relaxed assumptions: i) the matrices change negligibly in a short time window; ii) the human movements/IMU readings are diverse in such a time window. Intuitively, the first assumption reduces the number of candidate matrices, and the second assumption provides diverse constraints, which greatly reduces the solution space and allows for accurate estimation of R G′ G and R BS from a short history of IMU readings in real time. To achieve this, we created synthetic datasets of paired R G′ G , R BS matrices and IMU readings, and learned their mappings using a Transformer-based model. We also designed a calibration trigger based on the diversity of IMU readings to ensure that assumption ii) is met before applying our method. To our knowledge, we are the first to achieve implicit IMU calibration (i.e., seamlessly putting IMUs into use without the need for an explicit calibration process), as well as the first to enable long-term and accurate motion capture using sparse IMUs. The code and dataset are available at https://github.com/ZuoCX1996/TIC.

3
Citations
36
References
0
Implementations
Reusable
Repro status

Reproducibility Dossier

ReusableConfidence: editor verified / checked Apr 2026

GEOMDIGEST treats reproducibility as an evidence trail: public artifacts, documentation, data, packaging, archival stability, and verification checks. Numeric scores are only exposed for audited records; public pages prioritize the evidence itself.

1
Evidence
1
Verified
yes
Code
not yet
Data
not yet
Docs
not yet
Build checks
Methodology
Improve this dossier

Implementation Index

No implementations indexed yet

This paper is in the knowledge graph, but we have not attached a runnable artifact yet.

Citation Lineage

Selected paper
Transformer IMU Calibrator: Dynamic On-body IMU Calibrati...
2025 / 3 citations
Cited by0